6/9/21 workday

1st job: 

This was a refrigerator I fixed under my warranty…. I installed a new defrost timer because it started having defrost issues again after I put in the heater and thermostat….

Anyways the defrost timer didn’t change anything and the customer opted to replace this time and thanked me for my efforts….

 

 

2nd job:

I replace the evaporator fan motor of a refrigerator I diagnosed earlier last week….

An LG Top Freezer refrigerator model…..

 

This was a simple job…….. I just removed the entire evaporator cover, unscrewed the old motor, put the new one in, case closed…..

 

 

3rd job:

This was a GE HOTPOINT refrigerator…… the refrigerator is not cooling optimally…. So I take apart the evaporator cover…..

Anyways I let the refrigerator run for 30 minutes after I unplugged it initially to observe the evaporator coil…. The frost pattern is only appearing on the bottom coils while the top stays dry.

This is the beginning of a sealed system issue, I told the customer the costs associated with such a repair and he opted to replace..

Case closed!

 

 

 

Similar Posts

Leave a Reply

Your email address will not be published. Required fields are marked *